• 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
  • 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
  • 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
  • 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
  • 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control

0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Single
Usage: Single-Phase Transformer
Samples:
US$ 4.8/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control pictures & photos
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
US $4.8 / Piece
Min. Order: 5 Pieces
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
GWSCCT Split Core
Core
Core-Type Transformer
Cooling Method
Dry-Type Transformer
Winding Type
Multi-Winding Transformer
Certification
ISO9001-2000, UL, ISO9001, CCC
Frequency Characteristics
50-60Hz
Shape of Core
Toroidal
Brand
Grewin
Rated Primary Current
100-5000AAC
Rated Secondary Current
5 or 1AAC
Rated Load
1, 2.5, 5.0, 10, 30va
Accuracy
0.5, 1.0, 3.0 Class
Rated Short-Time Thermal Current (Ith)
20in
Rated Dynamic Current (Idyn)
2.5ith
Case Material
UL Flame Retardant Rating 94-V0
Highest Voltage for Equipment Um (RMS
720 VAC
Rated Power-Frequency Withstand Voltage
3, 000 VAC
Frequency Range
50/60Hz
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Trademark
grewin
Origin
China
HS Code
850450000
Production Capacity
50000 PCS /Week

Product Description

Basic Info:0.333-3.53V 1.0s 0.5s  IEC 60044-1 standard 50A 100A 200A 250A 300A  split Current transducer CT for HVAC temperature control  

Model NO.: 0.333-3.53V current transformer
Rated Load: 1, 2.5, 5.0, 10, 30va
Highest Voltage for Equipment Um (RMS): 720 VAC
Frequency Range: 50/60Hz
Rated Power-Frequency Withstand Voltage;: 3, 000 VAC
Output Split Core CT: Standard:IEC 60044-1
Trademark: Grewin
Transport Package: Export Standard Carton
Specification: ETL, CE approval
Origin: China
HS Code: 85045000

Product Description


0.5-600A 0.333V Transformer Split with ETL0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
TIANJIN GREWIN TECHNOLOGY CO.,LTD.
GWSCCTSA series split core current transformer  
Part number Rated input(A) Second output(V) Accuracy class Limit primary current(A) Accuracy class Frequency(Hz) OutlineDimensions ID-L-W-H(mm) Unit weight Turn ratio Output cable
GWSCCTSA005 5  10  15 0.333 1.0 3.0 - - 50-400 5.0-25.0-22.5-34.5 30g 3000:1 wire(1m)
GWSCCTSA010 5,10,20,50,75 0.333 1.0 3.0 120 5P 10P 50-400 10-29.4-26.4-41.7 50g 3000:1 wire(1m)
GWSCCTSA016 75,100,150 0.333 0.5 1.0 300 5P 10P 50-400 16-36.9-39.2-52.9 100g 3000:1 wire(1m)
GWSCCTSA024 100,150,200,250 0.333 0.5 1.0 540 5P 10P 50-400 24-51.2-47-70.2 250g 3000:1 wire(1m)
GWSCCTSA035 200,300,400,600 0.333 0.5 1.0 600 5P 10P 50-400 35-65.8-51.2-83.5 400g 3000:1 wire(1m)

0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control

GWCTSA Series Split Core Current Sensor (Specifications)

Rated Primary current

5-600A

Rated Secondary current

0.333V-3.53V

Rated load

1, 2.5, 5.0, 10, 30VA

Accuracy

0.5, 1.0, 3.0 Class

Rated Short-time thermal current (Ith)

20In

Rated Dynamic current (Idyn)

2.5Ith

Case Material

 UL flame retardant rating 94-V0

Highest Voltage for Equipment Um (rms)

720 Vac

Rated Power-Frequency Withstand Voltage(rms)

3,000 Vac 

Frequency Range:

50/60Hz

Operating Temperature

 -15ºC to 50ºC

Standard

IEC 60044-1

Accessories

Supplied with feet for base mounting if required

Certification

RoHS compliant CE&ETL approved

GWSCCTSA Series Split Core Current Sensor  (Features)

Low cost

5 standard sizes

Split core design, safer, easier installation, and portable

GWSCCTSA Series Split Core Current Sensor  (Applications)

Measures AC current flow to electric motors, lighting, air condition equipment, etc. 

Compatible with HVAC temperature control, power management, building 

The GREWIN SCCTSA series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits a safer, easier and portable current measurement.
0.333-3.53V rated secondary output split core current transformer :
 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control

Model No 1 :GWSCCTSA010
Ratio : 3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s  3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
 
Model No.2 :GWSCCTSA016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection 
 0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control

Model No. 3:GWSCCTSA024
Ratio : 3000:1 
Rated input: 100A 150A 200A 250A 
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
 
Model No.4:GWSCCTSA035
Rated input: 200A 300A 400A 600A
 Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control



CONTACT INFO:
Alice.Lee
TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .
 
 
Web: transformer.en.made-in-china.com


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control pictures & photos
0.333-3.53V 1.0s 0.5s IEC 60044-1 Standard 50A 100A 200A 250A 300A Split Current Transducer CT for HVAC Temperature Control
US $4.8 / Piece
Min. Order: 5 Pieces
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
501~1000 square meters
Management System Certification
ISO 9001