• Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
  • Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
  • Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
  • Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
  • Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
  • Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring

Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring

Application: Power, Electronic, Instrument, Lighting, Rectifier
Phase: Single
Usage: Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Samples:
US$ 6.23/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring pictures & photos
Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
US $6.23 / Piece
Min. Order: 1,000 Pieces
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
GWCTSB serie
Core
Core-Type Transformer
Cooling Method
Dry-Type Transformer
Winding Type
Auto-Transformer
Certification
ISO9001-2000, UL, ISO9001, CE, SGS
Frequency Characteristics
Intermediate Frequency
Shape of Core
Od
Brand
Gw
Power Rating
0.6va
Rated Loadd
1, 2.5, 5.0, 10, 30va
Rated Secondary
Ma or 0.333-3.53VAC
RoHS Compliant: CE-Approved
Rated Primary Current: 100-300AAC
Frequency: 50/60Hz
Operating Voltage:600VAC
Isolated Voltage: 2,500V AC
Coil Structure: Toroidal
Accuracy Class:: 0.5, 1.0, 3.0 Class Co
Low Cost: Water Proof
Shell Material:PBT or ABS
Leads:: 0.8foot(240mm), UL 1015, Twisted Pair, 0.34
Secondary Ratios Available: 5.0,1.0AAC
Phase: Single
Transport Package
Export Standard Carton with Strong Pallet
Specification
CE, RoHS, SGS, GMP
Trademark
Grewin
Origin
Tian Jin
HS Code
85045000
Production Capacity
500, 000 PCS/M

Product Description

Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring

Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
The GREWIN CTS series of split core current transformers
Are designed for fast and easy installation. The split
Core design permits non-contact current measurements
Through magnetic field induction without requiring that the
Primary wire be taken offline and disconnected for CT
Installation. This method permits a safer, easy and portable
Current measurement.Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
GWCTSB Series Split Core Current Transformer  (Specifications)
Rated Primary current 100-5000Aac
Rated Secondary current: 5 or 1Aac
 Rated load 1, 2.5, 5.0, 10, 30VA
Accuracy 0.5, 1.0, 3.0 Class
Rated Short-time thermal current (Ith) 20In
Rated Dynamic current (Idyn) 2.5Ith
Case Material  UL flame retardant rating 94-V0
Highest Voltage for Equipment Um (rms) 720 Vac
Rated Power-Frequency Withstand Voltage(rms) 3,000 Vac 
Frequency Range: 50/60Hz
Operating Temperature  -15ºC to 50ºC
Standard IEC 60044-1
 Accessories Supplied with feet for base mounting if required
Certification RoHS compliant CE&ETL approved
 
GWCTSB Series Split Core Current Transformer  (Features)
Low cost
5 standard sizes
Split core design, safer, easier installation, and portable
GWCTSB Series Split Core Current Transformer   (Applications)
Current, power, energy, monitoring devices
Relay protection devices
Power Factor Correction devices

 
An internal precision burden resistor across the secondary
Winding of the CT provides a safe low voltage output and
Permits safe opening of the secondary.
Measures AC current flow to electric motors, lighting, air conditioning
Equipment, etc. Compatible with HVAC temperature control, power
Management, building automation systems.

Rated Output: 0.333Vac
Accuracy: ± 1% from 10% to 130% of rated current
Phase Angle: Less than 2 degrees at 50% of rated current
Case Material: ABS Resin UL flame retardant rating 94-V0
Construction: Epoxy encapsulated housing
Insulation Voltage: 600Vac
Frequency Range: 50/60Hz
Operating Temperature: -15 to 60 Degree
Leads: 0.61m (2 Foot), UL 1015, Twisted Pair, 0.34mm² (22AWG),
The length can be customized

UL&CE recognized
Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring

PARAMETER:

Output secondary 5A split core current transformer :
Model 1:
GWCTSB0203
Turn ratio: 100:5A  150:5A   200:5A   250:5A  300:5A 400:5A current transformer China
Model 2:
GWCTSB0508
Turn ratio:250:5A 300:5A 400:5A 500:5A 600:5A 750:5A 1000:5A split core transformer
Model 3:
GWCTSB0512
Turn Ratio:600:5A 750:5A 1000:5A 1250:5A 1500:5A 2000:5A 3000:5A current CT
Model 4:
GWCTSB0812
Turn ratio: 500:5A600:5A 750:5A 1000:5A 1250:5A 1500:5A split core China
Model 5:
GWCTSB0816
Turn Ratio:500:5A 600:5A 750:5A 1000:5A 1250:5A 1500:5A high quality split core current transformer with ROHS ,ETL approval.
 
Output secondary rated 1A split transformer :
 
Model 1: GWCTSB0203
Turn ratio :100:1A  150:1A 200:1A 250:1A 300:1A 400:1A split core CT
Model 2: GWCTSB0508
Turn ratio: 200:1A 300:1A 400:1A 500:1A 600:1A 750:1A 1000:1A
Model 3: GWCTSB0512 
Turn Ratio:500:1A 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 3000:1A 
Model No.: GWCTSB0812
Model No.GWCTSB0816
Turn ratio: 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 2500:1A 3000:1A 4000:1A  split transformer ETL made in China

 
GRWEIN'S Split core current Transformer Typical Products                                                                        
Part
Number
Ratio Measuring Protection
Frequency
(Hz)
 
Outline
Dimensions
ID-L-W-H
(mm)
pdf
Rated Input Accuracy
Class
Rated Accuracy
Limit
Primary
Current
(A)
Accuracy
Class
 
CTGWSA005 3000:1 5,10,15 1.0
3.0
-- -- 50~400 5.0
-25.0-22.5-34.5
CTGWSA010 5,10,20,50,75 1.0,3.0 120 5P,10P 50~400 10
-29.4-26.4-41.7
CTGWSA016 75,100,150 0.5,1.0 300 5P,10P 50~400 16
-36.9-39.2-52.9
CTGWSA024 100,150,200,250 0.5,1.0 540 5P,10P 50~400 24
-51.2-47-70.2
CTGWSA035 200,300,400,600 0.5,1.0 600 5P,10P 50~400 35
-65.8-51.2-83.5
 
Photograph Part
Number
Rated
Input/Oput
(A)
Frequency
( Hz )
Accuracy
Class
Outline
Dimensions
(mm)
L-W-H
 
  CTGWSB0203 Input: 100,150,200,250,300,400
Output:5 or 1
50~400 0.5
1
3
105.0-89.0-40.0  
  CTGWSB0508 Input:250,300,400,500,600,750,
           800,1000
Output:1or5
50~400 0.5
1
3
145.0-114-48.0
  CTGWSB0512 Input:600,700,1000,1250,1500,
           2000,2500,3000
Output:1or5
50~400 0.5
1
3
192.0-143-49.0
  CTGWSB0812 Input:500,600,750,800,1000,1200,
           1250,1500
Output:1or5
50~400 0.5
1
3
185.0-144-48.0
  CTGWSB0816 Input: 1000,1200,1500,2000,3000,
     4000,5000
Output:1or5
50~400 0.5
1
3
247-176-52.0

Ratio 3000/1 2000/1 2500/1 3000/1 Split Current Transformer for Current Monitoring
(Product lines)


  Victor Dong


Tianjin Grewin Technology Co.,Ltd.
Web:  http://grewin-tech.en.made-in-china.com or transformer.en.made-in-china.com 
   
 
 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now