• 200A 2.5va Current Transformer for Energy Meter
  • 200A 2.5va Current Transformer for Energy Meter
  • 200A 2.5va Current Transformer for Energy Meter
  • 200A 2.5va Current Transformer for Energy Meter
  • 200A 2.5va Current Transformer for Energy Meter
  • 200A 2.5va Current Transformer for Energy Meter

200A 2.5va Current Transformer for Energy Meter

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer, Energy Meter
Phase: Single
Samples:
US$ 6/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
200A 2.5va Current Transformer for Energy Meter pictures & photos
200A 2.5va Current Transformer for Energy Meter
US $4.85-4.98 / Piece
Min. Order: 500 Pieces
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
GW-0021-40T-600A
Operation Condition
Outdoor
Usage
Protection, Measurement, Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-Rate Watt-Hour Meters, Maximum Demand Meter
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Active Type, Direct Connected
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Display
Digital
Electric Equipment
Single-Phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Certification
RoHS, ISO
Customized
Non-Customized
Type1
Current Transformer
Transport Package
Export Standard Carton Pallet
Specification
CE, UL, ROHS
Trademark
Grewin
Origin
Cn
HS Code
85044019
Production Capacity
10000PCS

Product Description

Current transformer mainly used in all kinds of electricity meter such as energy meter, water meter or electricity meter. We have current transformers both with and without DC immune. We can offer through-hole type, PCB type, Busbar type and flying wir type in mounting. Product with high accruacy up to 0.5, small phase error etc. We can also design and manufacture all kinds of current transformer according strictly to customer's special requirements.


Description:
1), All enclosed design, good performance of mechanical and insulation.
2), Pin design, easy to installate in PCB.
3), This series of CTs have small size that can be used as separate.
4), Linear output with high accuracy current.
5), Smalll size, light weight, standard hole easy to installation, Normal specifications and parameters as follow.
GW-0021-40T-600A Features:

1. Rated Primary Current: 200A
2. Rated Load: 2.5VA
3. Accuracy Class: 0.3L
4. Linearity Range: 0-3Times Rated Input Current
5. Operating Temperature: -25~+70 degree
6. Isolation Voltage: 2500VAC/min, 0.5mA
 
Single Turn Primary Mini Current Transformer(specifications)
Exterior Material PBT Resin UL flame retardant rating 94-V0
Interior Insulation Epoxy Encapsulated
Isolation Voltage 2500 Vrms for 1 minute
Dielectric Resistance 1000 M Ohms @ 500 Vdc
Surge Withstand 5000V(1.2/50μs standard  shock wave)optional
Rated Load Resistance 100K Ohms
Operating Temperature -25 to +55ºC,-40 to +85ºCoptional
Frequency 50 to 400 Hz
Accuracy Class defined in IEC 60044-1 Part 1 Voltage Transformers Class 0.1 0.2
Certification RoHS Compliant CE Approved
Single Turn Primary Mini Current Transformer(features)
Low cost
More than 50 standard sizes
Non-symmetrical mounting pattern
Toroidal Silicon steel and Nickel Alloy available
 
 
 
 
Single Turn Primary Mini Current Transformer(applications)
For applications that require exceptional accuracy with minimal phase angle error
Applications would include Voltage,power and energy monitoring devices
 
  

Photograph
Part 
Number
Rated
Input
Current
(A)
Turn
Ratio
Frequency
( Hz )
Secondary 
Burden 
Resistance
(Ohms)
Accuracy
Class
Outline 
Dimensions 
(mm)
  GWTA1111 5~30 1000:1
2000:1
2500:1
50 to 400 ≤200 0.1
0.2
0.5
ID-L-W-H
7.0-22.0-18.0-
23.0
  GWTA1311 5~80 ≤800 0.1
0.2
0.5
ID-L-W-H
8.0-25.3-18.0-
30.0
  GWTA1411 5~80 ≤800 0.1
0.2
0.5
ID-L-W-H
9.0-31.5-20.5-
33.5
  GWTA21A11 5~50 1000:1
2000:1
2500:1
3000:1
50 to 400 ≤200 0.1
0.2
0.5
ID-L-W-H
6.9-25.0-11.6-
26.5
  GWTA21B11 5~50 ≤200 0.1
0.2
0.5
ID-L-W-H
6.7-23.5-11.5-
25.0
  GWTA21CB11 5~15 1000:1
2000:1
50 to 400 ≤50 0.2
0.5
ID-L-W-H
3.6-18.0-10.0-
19.0
  GWTA21CE11 ≤50 ID-L-W-H
5.0-17.0-9.2-
16.7
  GWTA21CD11 ≤50 ID-L-W-H
5.0-18.0-10.0-
19.0
  GWTA21C11 1000:1
2000:1
2500:1
≤50 ID-L-W-H
4.5-18.0-10.0-
20.0
  GWTA21CA11 ≤300 ID-L-W-H
4.5-19.0-12.5-
19.0
  GWTA21E11 5~20 ≤200 0.1
0.2
0.5
ID-L-W-H
5-21-13.5-21.5
  GWTA21F11 5~30 1000:1
2000:1
2500:1
3000:1
≤200 0.2
0.5
ID-L-W-H
6.7-23.9-12-25
  GWTA22B11 5~80 1000:1
1500:1
2000:1
2500:1
3000:1
50 to 400 ≤800 0.1
0.2
0.5
ID-L-W-H
8.7-26-17.5-
27.5
  GWTA22D11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
9.0-29.5-19.0-30
  GWTA22E11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
12.8-36.7-14.2-
38.5
  GWTA2311 5~20 1000:1
2000:1
2500:1
50 to 400 ≤200 0.1
0.2
ID-L-W-H
5.0-18.8-17.8-
19.5
  GWTA23B11 5~80 1000:1
2000:1
2500:1
3000:1
5000:1
≤100 0.1
0.2
0.5
ID-L-W-H
6.0-25.0-21.5-
26.0
  GWTA23A11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
6.0-34.0-22.0-
36.0
  GWTA32B11 5~20 1000:1
2000:1
2500:1
50 to 400 ≤100 0.1
0.2
ID-L-W-H
5-17.6-19.3-
17.6
  GWTA3311 5~80 1000:1
1500:1
2000:1
2500:1
3000:1
≤500 0.1
0.2
0.5
ID-L-W-H
6.0-28.0-28.0-
22.0
  GWTA34B11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
5.5-34.0-34.0-
23.0

 

 
Part 
Number
Rated
Input
Current
(A)
Turn
Ratio
Frequency
( Hz )
Secondary 
Burden 
Resistance
(Ohms)
Accuracy
Class
Outline 
Dimensions 
(mm)
GWTA1111 5~30 1000:1
2000:1
2500:1
50 to 400 ≤200 0.1
0.2
0.5
ID-L-W-H
7.0-22.0-18.0-
23.0
GWTA1311 5~80 ≤800 0.1
0.2
0.5
ID-L-W-H
8.0-25.3-18.0-
30.0
GWTA1411 5~80 ≤800 0.1
0.2
0.5
ID-L-W-H
9.0-31.5-20.5-
33.5
GWTA21A11 5~50 1000:1
2000:1
2500:1
3000:1
≤200 0.1
0.2
0.5
ID-L-W-H
6.9-25.0-11.6-
26.5
GWTA21B11 5~50 ≤200 0.1
0.2
0.5
ID-L-W-H
6.7-23.5-11.5-
25.0
GWTA21CB11 5~15 1000:1
2000:1
≤50 0.2
0.5
ID-L-W-H
3.6-18.0-10.0-
19.0
GWTA21CE11 ≤50 ID-L-W-H
5.0-17.0-9.2-
16.7
GWTA21CD11 ≤50 ID-L-W-H
5.0-18.0-10.0-
19.0
GWTA21C11 1000:1
2000:1
2500:1
≤50 ID-L-W-H
4.5-18.0-10.0-
20.0
GWTA21CA11 ≤300 ID-L-W-H
4.5-19.0-12.5-
19.0
GWTA21E11 5~20 ≤200 0.1
0.2
0.5
ID-L-W-H
5-21-13.5-21.5
GWTA21F11 5~30 1000:1
2000:1
2500:1
3000:1
50 to 400 ≤200 0.2
0.5
ID-L-W-H
6.7-23.9-12-25
GWTA22B11 5~80 1000:1
1500:1
2000:1
2500:1
3000:1
≤800 0.1
0.2
0.5
ID-L-W-H
8.7-26-17.5-
27.5
GWTA22D11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
9.0-29.5-19.0-30
GWTA22E11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
12.8-36.7-14.2-
38.5
GWTA2311 5~20 1000:1
2000:1
2500:1
≤200 0.1
0.2
ID-L-W-H
5.0-18.8-17.8-
19.5
GWTA23B11 5~80 1000:1
2000:1
2500:1
3000:1
5000:1
≤100 0.1
0.2
0.5
ID-L-W-H
6.0-25.0-21.5-
26.0
GWTA23A11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
6.0-34.0-22.0-
36.0
GWTA32B11 5~20 1000:1
2000:1
2500:1
≤100 0.1
0.2
ID-L-W-H
5-17.6-19.3-
17.6
GWTA3311 5~80 1000:1
1500:1
2000:1
2500:1
3000:1
≤500 0.1
0.2
0.5
ID-L-W-H
6.0-28.0-28.0-
22.0
GWTA34B11 5~100 ≤1000 0.1
0.2
0.5
ID-L-W-H
5.5-34.0-34.0-
23.0



FEATURES:
Current transformers for electronic watthour meters with DC-tolerance are designed for applications where AC current signals or
half wave rectified DC current signals must be
transformed accurately into a lower current signal
appropriate for micro-processor based circuits.
A new TA model can be designed and manufactured to meet the specific
design challenges of the client's specific application. The following models
are only a small sampling of the many different products which have been
and are currently being manufactured.
Application:
Electronic watthour meters according to IEC 62053 -21, -23 must
have a tolerance to DC current
SPECIFICATIONS:
Case Material: PBT Resin UL flame retardant rating 94-V0
Construction: Epoxy Encapsulated housing
Isolation Voltage: 2500 Vrms for 1 minute
Insulation Resistance: 1000 M Ohms @ 500 Vdc
Surge Withstand: 5000V(1.2/50μsstandard shock wave)
Operating Temperature:-25 to +55ºC,-40 to +85ºC
Optional Frequency: 50 to 400 Hz
RoHS compliant
CE compliant
Accuracy Class: Compliant IEC 60044-1, Class 0.1, 0.2

200A 2.5va Current Transformer for Energy Meter
200A 2.5va Current Transformer for Energy Meter
200A 2.5va Current Transformer for Energy Meter


Tianjin Grewin Technology Co.,Ltd.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now